What I Would Do If I were Farming
I am not a farmer, but I grew up on the farm and have been involved in farming my whole life. In doing so I have learned a lot about grain aeration from doing research and analyzing data, as well as from my past farm experience.
What I would do:
1. I would have all my bins equipped with open bottom plenums and quick attach — ready for small aeration fans.
2. I would use small fans. Since the flow only goes up with the cubed root of the power (HP). In going from 7 HP to 1 HP, even though this is a drastic cut in power, the flow is not even halved. The capital cost is about a half.
POWER FLOW PRESSURE COST(Flaman)
10 HP 2,150 CFM 3.1 $ 2300
7 HP 1,91 2.6 $ 2100
5 HP 1,700 2.2 $ 1700
3 HP 1.44 1.732 $ 1300
2 HP 1,200 1.4 $ 1100 ??
1 HP 1,000 1.0 $ 900 ??
OPI temp cable is $400, while a moisture cable is $1000.
3. Since I have aeration, I would use it and start my harvest when the grain is tough (2 points above dry). So if wheat dry is 14.5 %,, then I would start combining when the MC is 16.5%. Getting an early start to harvest by a couple of days reducing the risk of having my grain exposed to the elements. Also I could start combining earlier in the morning and go later into the evening if I am willing to harvest tough grain.
4. We know that the bottom of the bin dries first, so I would put the tougher grain on the bottom, and the drier grain closer to the top. Starting the harvest day with tough grain,– put it on the bottom, even if it meant moving to a new bin.
5. Start the fans immediately, even while filling the bins. First day is critical.
6. Have a double temperature sensor (thermistor) hung in the center of the bin, half way down. I would use two thermistors because of redundancy and validation. The cable coming through the top hole and down the side of the bin would be available to check the temperature of the grain with a handheld device and it could also be used to plug into a controller on the fan.
7. The controller on the fan would be attached to the cable in #6 and also be able to measure the temperature of the outside air. The fan would turn on if: the outside air temperature < grain temperature. AND if the outside air had a relative humidity < adjustable RH (85% – 65%) So we need an adjustable RH sensor like the ones on humidifiers for residential furnaces.
8. To determine where to set the RH in #7, I would use the grain calculator. Set the grain temp, in the calculator, to what I measured the grain temp from the thermistors, the outside air temp also would be set to the grain temp; and the moisture content to my best guess as to what the moisture content is. When we first load the grain into the bin, we probably would know the MC, and then for every 15 C that we lower the grain temp, take a point off this initial MC. After all this is entered, push calculate and get the RH thres, looking through the list for the grain type in the bin. Set the RH on the controller to the RHthres. For example: let’s say we have barley that was loaded into the bin at 16% moisture (MC) and 30 C. The outside temp is 22 C and outside RH is 73%. So in the calculator we enter 16 for the MC, 30 for Grain Temp, and 30 for the outside air Temp. Push Calculate, the RHthres for Barley comes up as 75.9%. So we set the RH on the controller to 76%. Will the fan turn on? Yes, the outside air < grain temp (22<30 ) AND the outisde RH is less than the setting (73% < 85%). We come back the next day and we find that the barley has cooled to 20 C so we should take two thirds of a point off 15% -> 15.4%. Each day we check: First day second day third day fourth day fifth day
Moisture Content 16% 15.4% 15% 14.9% 14.9%
Grain Temp & Air T 30 20 15 13 12.9
RH set to RHthres 75.9 70.7 67.2 66 66
Why do we set the Air Temp in the Calculator to the Grain Temp? Because that is the worst case RH, and it sets the Absolute Humidity. If this is graphed on the Psychrometric Chart we see that as the temperature gets colder, the same RH produces a smaller Absolute Humidity Value. Or even drier air is required to turn the fan on. Lowering the setting on the RH knob will also lower the duty cycle of the fan, as it should because we are starting to cherry pick and have the fan on only when there are good drying conditions. If we are in a little more of a hurry to dry our grain, then we should leave the RH setting higher. This would be at the risk of having the fan run when there are slight wetting conditions when the grain temp and air temp are almost the same. But it will not miss as much of the drying conditions.
9, Supplemental Heat: See the other blogs on supplemental heat. This is only required if the MC is more than 2 points above dry. There is no way around it, it will cost money to dry the grain — but I do think it can be done for about 10 cents per bushel per point dried. I have worked out a number of examples in previous blogs. In general we want to heat the grain during the day, using the naturally higher temperatures of the day, and then cool at night using the cooler dry night air. Use the rule of thumb. For every 15 C cooled is a point removed MC.
10. For a bin that is a bit stubborn in getting dry. I would tip the bin by taking out a few hundred bushels from the bottom to invert the cone at the top.
11. Seal the bin in January after we have cooled the grain down as cold as possible. Get the mindset. The colder the better. The colder the safer.
You might ask why I would go with the differential temp controller as opposed to the absolute humidity controller. Yes, the absolute humidity controller is theoretically the best, and controls the fan such that it catches all the times we have drying conditions. The differential controller misses some slight drying times because we are not willing to sit there and do the calculations every hour, so we set the RH to the worst case. However when one considers the cost, simplicity and reliability I think it is the better choice. The overall system is inexpensive and you don’t really need the expensive internet monitoring, or computing. The controller on the fan is very simple, inexpensive and reliable. The absolute humidity controller requires a calculation of the absolute humidity, which is fairly complicated. As well we must rely on relative humidity sensors that I have found to be expensive, not that accurate and not that reliable. I have had many RH sensors go bad on me. Any foreign material that gets on the film — they are toast. So the absolute humidity controller is fine for the perfectionist who demands the optimum (the researcher); but a farmer is looking for the best answer in getting the job done with a balance of effectiveness, cost, and reliability.
If one goes out and manually checks to make sure the temperature of the bin is low i.e. that the system is working, then we know that our grain is safe, not spoiling and really that’s the most important thing.
What RH is low enough to Dry?
I have been asked this question again and again and the first thing I say is that the temperature is more important than the Relative Humidity (RH). So first, only turn the fan on if: OutSide Air Temp < Grain Temp.
However, doesn’t the RH of the outside air and the Moisture Content (MC) of the grain also come into play? Absolutely. And the way we can answer this question is to use the calculator planetcalc.com/4959/ Make the grain temp and air temp the same and try at 10 C 20 C 30 C and calculate corresponding RHt
Flax 9% MC 61.6% 66.2 70.4
Flax 10% MC 68.1 72.1 75.6
Flax 11% 73.2 76.7 80
Flax 12% 77.4 80.4 83
Wheat 16 73.5 75.6
Wheat 15 68.3 70.6
Wheat 14 62.4 65
Yellow Peas 16 73.5 75.6
Yellow Peas 15 69 71.3
Yellow Peas 14 63.8 66.4
Conclusion: If one is to build a controller that is controlled by temp, that is:
Fan On IF: Outside Air Temp < Grain Temp on must also consider RH,
AND Outside Air RH < 80% to start when grain temp and MC high
< 70% when grain cooled and MC close to dry
We almost need to have the RH on a variable knob, so that on the first day when we first start the fan after filling the bin, the grain is warm and maybe a little on the tough side, we put the RH knob to 80%. After a day or so, the grain will have been cooled down, and therefore drier, so we might put the knob at 75%. And then, maybe after a week or so we turn the knob down to 70%. Following this practice should keep the grain cold and only have the fan on when we have drying conditions. This would make for a simple reliable controller that would keep the grain safe and dry.
CFM calculations for 2017
The following are calculations for the CFM and CFM/bu. for the eight bins we had trials on for 2017. We measured the airflow into the fans in km/hr. so the first conversion is to get this into ft/min because we eventually want to get to cubic feet per minute.
kmph –> ft./min 1 kmph = 0.9113 ft/sec = 54.678 ft./min H2O pressure
Bin 18 (3500 bu, Diam 23″) 11.2 km/hr x 54.678 = 612.4 ft/min x Area (pi r^2) 23/12/2 2.88sq ft = 1767 CFM /3500 0.50 CFM/bu 5.5″/7.4″
Bin 19 (3500 bu, Diam 23″) 11.2 km/hr x 54.678 = 612.4 ft/min x Area (pi r^2) 23/12/2 2.88sq ft = 1767 CFM /3500 0.50 CFM/bu 5.5″/7.4″
Bin 9 (2200 bu, Diam 15″) 30 km/hr x 54.678 = 1640 ft/min x Area (pi r^2) 15/12/2 1.22 sq ft = 2013 CFM /2000 1.0 CFM/bu 3.25″/5.0″
Bin 10 (2200 bu, Diam 15″) 30 km/hr x 54.678 = 1640 ft/min x Area (pi r^2) 15/12/2 1.22 sq ft = 2013 CFM /2000 1.0 CFM/bu 3.25″/5.0″
Bin 15 (10000 bu, Diam 15″) 70 km/hr x 54.678 = 3827 ft/min x Area (pi r^2) 15/12/2 1.22 sq ft = 4669 CFM /10000 0.466 CFM/bu 6″ (inside )
Bin 14 (5000 bu, Diam 15″) 85 km/hr x 54.678 = 4647 ft/min x Area (pi r^2) 15/12/2 1.22 sq ft = 5669 CFM /5000 1.13 CFM/bu 5″
Bin 16 (3500 bu, Diam 16″) 18 km/hr x 54.678 = 984 ft/min x Area (pi r^2) 16/12/2 1.39 sq ft = 1373 CFM /3500 0.3925 CFM/bu 5″/6″
Bin 16 (3500 bu, Diam 16″) 18 km/hr x 54.678 = 984 ft/min x Area (pi r^2) 16/12/2 1.39 sq ft = 1373 CFM /3500 0.3925 CFM/bu 4.8″/5.75″
The pressure is in inches of water ; the first number is outside the plenum and the number after the / is the inside of the plenum, so you can see the pressure drop across the perforated holes in the pipe.
Duty Cycle of Absolute Humidity Controller
I took a look at the duty cycle (on time/total time) for the different bins:
Delage Bins Start End Percent Duty Cycle (on time/total time)
Bin 14 Aug 11 to Aug 21 73.6%
Bin 15 Aug 11 to Aug 21 64.8%
IHARF Bins
Bin 17 Aug 30 to Sep 6 94%
Bin 19 Aug 22 to Sep 6 95.6%
The IHARF bins were on almost constantly. And what is really strange is that the absolute humidity in the bin would increase, even when it was blasted with air that had a lower absolute humidity. I can’t explain it? Maybe it has to do with sensor placement in the bin? Were we really sensing or getting a true sample of the the exhaust air? Or perhaps we just had really good drying conditions for the period of time that we did the run? I would think that the Delage bins would be closer to the norm as far as duty cycle goes.
Grain Drying Calculator Update
I have added soybeans and yellow peas to my grain drying calculator at planetcalc.com/4959/ This calculator gives the relative humidity, below which, drying will occur. It only requires the temperature and moisture % of the grain, as well as the outside temperature and by using EMC equations it calculates the absolute moisture in the air, entering and leaving the bin. It can be easily loaded onto an Iphone.
Weyburn Presentation
The following is my latest presentation, done originally in power point. The presentation typically takes one hour to deliver and is intended to be interactive with questions during and after it. It is somewhat dry without having commentary but can be instructive just the same.
Weyburn 2017
2017 MFSA Forage Seed Conference: Grain Aeration — The Truth Revealed
On January 9 I will presenting at the MFSA Seed Conference at the Victoria Inn in Winnipeg. I am scheduled for 11:30 and I will be presenting the fundamentals of grain aeration and even a little bit about supplemental heat. If you happen to be in the area, drop by.
Supplemental Heat: Act V Using the Grain Drying Calculator, A Balancing Act
I have blogged about the grain drying calculator, http://planetcalc.com/4959/
I explained how to use it without supplemental heat, but not how to use it when supplemental heat is used. The short answer is that you use it in the same fashion. You still enter the moisture content of the grain, the temperature of the grain, and the ambient outside temperature of the air (before it is heated). The resulting RHthres will indicate whether or not drying will occur.
One might conclude, that you will get the same answer for RHthres whether you are applying heat or not; and this is quite true — at first, but if heat is applied the temp of the grain will increase. My Act III blog on Supplemental Heat indicated that it would take 12.3 hours to heat the grain 5 ºC with a 50,000 btu heater. However I failed to mention the two implied assumptions: 1) that the grain body heated up uniformly and 2) the ambient outside temp remained the same. Neither of these assumptions are true.
The grain will heat at the bottom of the bin first, and the so called “warming-front” will slowly work its way to the top. If you have a cable with multiple temperature sensors, you will see this first hand.
The ambient air temperature also varies by 10-15 ºC. The air going through the heater will get a boost in temperature, above the ambient, by maybe 20-30 ºC. So, let’s say the outside air temperature has a low of 5, and a high of 15; and the temperature rise through the heater is 30 C. Let’s say we turn the heater on when it is cold outside, 5 C and so is the grain, 5 C. After one hour, the bottom of the bin might increase to 10 C, while the top stays at 5. After two hours the grain will be even warmer at the bottom, maybe 15, and as time goes on the bottom will get warmer and warmer with a wave of heat slowly creeping up the bin. We have a string of temperature sensors, so we can actually watch this wave. Eventually the top of the grain will also be getting warmer.
Now comes the tricky part, when should the heat be turned off in order to curtail condensation? Remember we never want the top of the grain temperature to exceed the outside ambient temperature by more than 5 C. Let’s say that we are approaching the highest temp of the day, 15. Maybe the top of the grain is 10 C, and the bottom 30 C. Everything is fine — no condensation — yet. As the day cools off, to 5 C, the wave of heat will continue to heat the grain at the top, even if we turn the heat off. In a few hours the top of the grain may become 15 C and as we approach the low of the day, 5C — we will have conditions for condensation — the grain is 10 C higher than the ambient temp.
What would be ideal would be to apply heat such that the top layer of grain is always 5 ºC warmer than the outside air. There are two difficulties with this. First there is a huge delay from the time we apply heat at the bottom until it reaches the top layer. It would be hours, and it depends on so many things, such as air flow rate, heater size, bin size, etc. And to anticipate this delay is really difficult. The other complicating factor is that the ambient temperature changes, and sure we can get a forecast of the temperature, it is not entirely accurate. And then to monitor and control this whole mess.
Let’s take on the heat wave delay problem. The outside air goes up and down in temperature in a somewhat predictable fashion. Somewhat of a sinusoid in shape, with the warmest part of the day taking place a couple of hours after noon, and the coldest part of the day a couple hours after midnight. Typically we see a difference in the high to low temperature of 10 – 15 ºC. We ideally would like to apply supplemental heat such that the top layer of grain is always 5 to 6 degrees warmer than the outside temp. The problem is there is a delay in applying the heat to the bottom of the bin to when it gets to the top. What is this delay? To determine the delay we could model the system, but this is a trickly onerous task — and there are so many variables. The other way to find out what this delay is, would be to review the data of our runs, and see what it is. I did just that, and I examined two trial runs, 9 10P and 09 09W. Clearly the delay was close to 6 hours. The flow was close to 1.2 CFM/bu and if we lowered the flow to 0.3 CFM/bu we would increase the delay accordingly to 24 hours. The temperature of the top layer of grain will be synchronized with the daily cycle of temperature change of the outside air. We can use the rate of flow of air to adjust the delay and set it where we get a 24 hour delay.
Now the other problem, we want to add supplemental heat to keep the top layer of grain 5 to 6 ºC above ambient, we want a 5-6 ºC rise, throughout the whole day. We would keep the fan running continuously, and the heater running continuously to provide a 5 C rise. What size heater do we need for this?
In my earlier blog: “Big Heater for supplemental heat Example” I had a farmer with a 1.4 million btu/hr heater at 5,000 CFM. It produced a 30 C rise in temp. Supposing we have a 3500 bushel bin, we would need 1000 CFM to get the synchronizing daily delay of 0.3 CFM/bu. The rise we would get with a 50,000 btu furnace would be 50,000/1,400,000 x 5000/1000 x 30 = 5.35 ºC — Perfect. A 50,000 btu furnace with 1000 CFM should do the job to give a 5 C rise with a 24 hour delay. We might have to use some trial and error to fine tune this.
Review: Aerating Stored Grain — Australian Guide
I was going through my files, and I came across an aeration guide that Guy Lafond had given me in 2011, along with his annotations. It can be found at http://www.graintec.com.au/media/34545/Aerating%20stored%20grain%20-%20A%20Grains%20Industry%20Guide.pdf
It is called Aerating Stored Grain, Cooling or Drying for Quality Control, A grains Industry Guide by GRDC (Grains Research & Development Corporation) in Australia.
Guy passed away a couple of years ago, and in going through the report and reading his notes, it is almost as if he is talking to me. I must have skimmed the report, but it is only now that I have slowly read the report and have appreciated the annotations. Many of the findings in the report are in agreement with what we have found, and then there are guidelines that do not. I will now go through the report and perhaps in a somewhat disjointed way touch on the issues of agreement and disagreement. You be the judge, and try to discern where the truth lies. Quotes from the booklet will be in italics, followed by my comment and Guy’s note.
This booklet explains the key differences and processes involved in aeration cooling and aeration drying. We discovered right from the start of our analysis that cooling the grain also dries it. The two are not separate process, cooling is drying. In fact this relationship can be approximately be quantified: cooling the grain by 15 ºC reduces the moisture content by one percent.
38 per cent is air space around each grain. You may have noticed that we used 40% in the calculations done in my blogs.
Without circulation, the air surrounding the grain will reach a moisture (relative humidity) and temperature equilibrium within a few days. In other words, you must leave your grain in a sealed bin for three days before you will get an accurate reading on your moisture cables. Moisture cables use Equilibrium Moisture Content to calculate moisture; the air and the grain must be in equilibrium. The fans must be off for a long time to achieve equilibrium. In other literature, I have seen times like 3 hours to reach equilibrium. In actual fact, equilibrium is never reached, it is said to be asymptotic. It gets closer and closer but never reaches it. That is why in my blogs I introduced the notion of a time constant, which is the time it takes to get about two thirds the way there. Anyway the huge lesson here is that moisture cables can only give an accurate reading of Moisture Content if the fan is off for a considerable time.
The air in the head space, heats and cools each day creating ideal conditions for condensation to form, wetting the grain at the top of the stack. The good news is that this guide does recognize a problem with condensation; the bad news is that they don’t give the specifics of the conditions that create condensation. Using my calculator, http://planetcalc.com/4959/ we do have the specifics of when condensation occurs: it is whenever the RHthres is above 100%. The more it is over 100, the more the condensation. It turns out that the rule of thumb is this: If the grain in the bin is more than 5º C warmer than the outside air, there are conditions for condensation. The more the temp. difference, the more the condensation.
Grain aeration systems are generally designed to carry our either a drying or cooling function — not both. This is what Guy had in his note on this: “Not so, drying occurs as grain is cooling”. Guy and I learned this by analyzing the data collected from bins with aeration since 2007.
Aeration cooling can be achieved with airflow rates of 2-3 litres per second per tonne delivered from fans driven by a 0.37 kilowatt (0.5 horsepower) electric motor. I agree that low flows can achieve cooling within a matter of hours, and look at the size of the motor to do this , half a HP. What I don’t agree with is that only cooling will take place with low flows; drying also takes place. Remember the rule of thumb that was developed from analyzing our data: Cooling the grain by 15 ºC removed 1% moisture content — regardless of the air flow rate. In fact, I propose that more water will be removed with lower fan rates in terms of cooling. We can make better use of the energy in the grain, to evaporate water if we do it a little slower, with lower air flow rates. See my blog on air flows.
Aeration drying can be achieved with fans delivering 15-25L/s/t, typically powered by 7kW (10hp) electric motor. Again the message here is that only large air flows can dry grain; I disagree. Lower flows are actually more effective; not in terms of time, but in terms of actual moisture taken out. Once we have taken the energy (heat) out of the grain, drying will no longer occur — with high or low flows. The trick is to use as much energy as we can for drying. I think we can use this energy more efficiently to remove the water, if we go a little slower with lower flows.
Grain that is dry enough to meet specifications for sale (12.5% for wheat) can be cooled without drying. I beg to differ, cooling is drying. Guy’s comment was “really?”
After drying to the required moisture content, cool the grain to maintain quality. Guy’s comment to this: “Cooling and drying occur together”
Aeration cooling moves the air pockets around the grain, which evens out any hot or moist areas, creating a uniform stack. Notice here they are talking about aeration cooling that use low air flows. Therefore low air flows even things out, they do not create pockets or fronts of moisture or temperature. I agree.
One way of measuring change in grain quality over time is seed germination. Exactly, this is what I have done by calculating the number of safe days, and the spoilage index. It is sometimes uncanny how the same conclusion can be reached independently.
Stored grain deteriorates with time under any conditions, but poor storage conditions (high temperature and moisture) accelerate the deterioration process markedly. I agree, you can’t stop spoilage, you can only slow it down. Grain in storage can never improve in quality, it can only get worse.
If aeration cooling is being used to hold moderately high-moisture grain temporarily until drying equipment is available, run fans continually while the ambient relative humidity is below 85 percent. Guy notes: “Interesting Concept, Not sure if I agree.” Again we have the assumption that low flows do not dry — but they do. And where did the magic 85% come from? What is it based on? I can show you tons of examples where drying takes place with RH above 85, and tons of examples where wetting takes place with the RH below 85. We are missing some important parameters here like grain temp, and air temp.
However, do not operate the aeration fans on continuous mode for more than a few hours, if the ambient relative humidity is higher than 85 per cent. Again, where does this magic 85% come from? And again, there are important parameters missing. Guy notes: “Depends on Tº “.
After aeration fans have been running continuously to flush out the warm, humid air for 2-3 days, reduce run time to 9-12 hours per day for the next 3-5 days. The difficulty is selecting the coolest air to run the fans and being on site to turn the fans on and off. This is interesting and very close to my recommendation that the fan should be turned on, even as the bin is being loaded, and run until 9 the next day after which you only run the fan during the night, or the coldest hours. Not during the day, with the hottest hours? We learned that cooling is drying, and you can only cool if the air is colder than the grain. The Aussies already knew this long before we did.
During this final phase they continually monitor ambient conditions and run fans on average during the coolest 100 hours per month. Every time we pull the temperature of the grain down, we will be doing some drying, and by keeping it as cold as possible, the grain will be as safe as possible with the least spoilage. It is interesting that monitoring the ambient conditions is required, but exactly what are these ambient conditions in which one should run the fan?? I am suggesting that the fans be on if, and only if the air temp is less than the grain temp. and the RH < 80%. We have found that if you follow this rule, that the fan duty cycle will be < 20% which is about 144 hours per month– amazingly close to 100 hours. Again, we have arrived at the same conclusion — independently.
Growers and bulk handlers need to have an understanding of the effects of relative humidity and temperature when aerating grain. I could not agree more, but the problem is, the report, is not giving us any understanding of the effects. Specifically, what temp and RH should I run the fan? My calculator provides exactly what the temp and RH of the grain and ambient air should be to provide the conditions for drying AND for the conditions of condensation.
However, drying depends completely on the airflow through the grain. I do not agree. Grain will dry quite nicely, perhaps even more efficiently with low flows.
Operating in drying mode, aeration controllers select for air with low relative humidity. Guy notes “Why only RH and not T as well ?” They seem to keep missing the point that the amount of water in the air is determined not only by its RH but also, and maybe even more so, by its temperature. They are missing the pyschrometric equation that relates RH and T to absolute humidity.
In rare situations aeration cooling fans can reduce grain moisture slightly, but they cannot reliably reduce grain moisture to a safe level. I disagree. The amount of drying depends on how efficiently we can use the energy in the grain to push the water out and evaporate it into the air. Low air flows will do this as well as high air flows. I would argue that low air flows actually do it better.
Much higher airflow rates are required for aeration drying in order to push a drying front through the grain bulk. I disagree; in fact it is the larger airflow with the increased compression on the bottom of the bin that leads to over-drying the bottom and under-drying the top. And there really is no drying front, it is more like a continuum, with the bottom being dried first and the top last. And this is done more evenly if we have less compression on the bottom with a smaller fan and less flow.
Wheat at 16.5% MC at a temperature of 28 ºC was put into a silo with no aeration. Within hours the grain temperature reached 39 ºC and within two days it reached 46 ºC providing ideal conditions for mould growth and grain damage. Guy notes: “I am not sure I agree with this.”
By monitoring the temperature and moisture content of the grain in storage, and reading the equilibrium tables for wheat or sorghum at the back of the booklet, a suitable relative humidity trigger point can be set. Guy notes: “How to consider equilibrium moisture content?” This suggests that I can take the temperature of the grain (let’s say 25) and the MC (let’s say 15%) and apply this to the EMC table to get a trigger RH of 82%. What could be simpler? Well, we missed a very major point: The ambient air is NOT the same temperature as the wheat, therefore one can not consider the system to be in equilibrium and therefore the EMC table does not apply. The trigger RH of 82 is for the air inside the bin, at equilibrium and at the same temperature as the wheat. We can and do calculate the corresponding RH for the air outside with my calculator — but I would say that this important point is almost always overlooked or perhaps just not understood.
Firstly, warm air can transfer moisture from the grain more efficiently than cold air. Guy notes: “Depends on RH?” This has been a hang up with people for some time, and at first glance it seems obvious, of course warm air can dry better than cold air!! But, wait a minute let’s examine this more carefully. Drying occurs when the vapour pressure of the grain is larger than the vapour pressure of the air. Vapour pressure depends on the moisture content and more importantly the temperature of the grain or the air. When the grain temp is higher than the air temp, it most likely has a higher vapour pressure and drying occurs. There are exceptions and one can conjure up an example where the air is just slightly cooler than the grain, at 100% RH and then wetting will occur. But, as has been said in this report, with air, RH < 85%, and a temp less than the grain, you are assured that you have drying conditions. Sure warm air can hold more water than cold air, but the point that has been missed is that the warm air becomes the same temp as the grain as soon as it hits it. If the grain is cold, the air will also become cold, and the air will not be able to hold the water it has, exceed 100% RH and dump the water onto the grain. The warm air, that we thought was capable of carrying more water, and it could have if it stayed warm — but it doesn’t, it becomes almost the same temperature of the grain. Sure eventually the grain will become the same temperature of the outside air, after hours and hours, but guess what by then the outside temperature has changed. The outside ambient air temperature and the grain temperature are NEVER the same. Yet people assume they are. Big mistake.